| F.P.
Engineering are the Southern African arm of C.T.P in Austria
with the rights to market and manufacture the R.T.O units under
the C.T.P umbrella with the design undertaken in Austria. |
| |
| We together
with C.T.P. would like to introduce you to "The route to efficient
air pollution control". C.T.P. is one of the leaders of pollution
control in Europe with inhouse research and highly experienced engineers
and supply the optimal control system for the destruction of: |
| |
1) Volatile
Organic Compounds (VOC)
2) Carbon Monoxide
3) Hydrogen Sulphide
4) Nitrogen Oxides
5) Dioxins
6) Organic Particulate Matters |
| |
| The
R.T.O's - Regenerative Thermal Oxidizers - are designed to
cope with fluctuating flows and concentrations of raw gas at lower
operations cost than thermal recuperative oxidizers. The use of prismatic
ceramic honey combed in the heat exchanger enlarges the heat exchanger
area three and a half times with the pressure drop in the autotherm
remaining very low. |
| |
| The
plant is operated by a fully automated control system. We offer a
number of options on control systems, all of which are easy and safe
to operate. The modular design of autotherms enables additional units
to be added if higher efficiency or a larger capacity is required
at a later date. |
| |
| COMPACT
RTO MULTI-BED SYSTEM |
| |
| High
Purification rate 99.9+ % |
| Low
or High VOC Concentrations - we easily surpass the directives |
| |
| |
| |
| Typical
CTP Multi-Bed Installation |
| |
| |
|
| |
| How
It Works ... |
Valve
Box |
|
| |
| New
Generation of compact multi-bed RTO's |
| |
- Very
high destruction efficiency (>99.9 %)
- Low
Pressure Drop (17 to 29 mbar)
- High
Thermal Efficiency (> 97 %)
- Simple
System consisting of separated inlet and outlet regenerative
heat exchangers ensuring gas tightness and spanned by a
single combustion chamber which guarantees perfect mixing
and minimal radiation loss.
- Reliable,
quick acting, impervious poppet valves which boast countless
hours of fail-safe operation owed to CTP's smart and durable
design
- Weatherproof
instrumentation and heating system
- CTP's
hot bypass caters for a wide range of solvent concentrations
and can rapidly adapt to varying inlet conditions (flow
fluctuations, concentration peaks)
- CTP's
bake-out procedure eliminates particulate build-up and through
its ability to adjust duration and temperature has proved
its effectiveness in many challenging applications
- Advanced
and enhanced heating technology featuring 3 options:
burner / electrical heater / direct fuel injector
|
| |
| |
| |
|
| Type |
Nominal
Flow [NM3 / h] |
Length
mm |
Width
mm |
Height
mm |
| |
| TT025V |
3.200 |
3.200 |
2.500 |
3.300 |
| TT050V |
4.800 |
3.800 |
2.500 |
3.300 |
| TT075V |
7.200 |
4.700 |
2.500 |
3.300 |
| TT100S |
9.600 |
4.800 |
3.500 |
3.800 |
| TT125S |
12.000 |
5.400 |
3.500 |
3.800 |
| TT150S |
14.400 |
6.000 |
3.500 |
3.800 |
| TT175S |
16.800 |
6.600 |
3.500 |
3.800 |
| TT200M |
19.800 |
6.200 |
4.900 |
3.800 |
| TT250M |
23.400 |
6.800 |
4.900 |
3.800 |
| TT300M |
27.000 |
7.400 |
4.900 |
3.800 |
| TT350M |
32.400 |
8.300 |
4.900 |
3.800 |
|
| |